AUPT design
We design the system: suppression type, calculations, pump station. We integrate it with fire alarm systems and notification systems.
Automatic fire suppression systems (AUPT) across Tashkent & Uzbekistan: design, calculation and installation — water (sprinkler & deluge), gas and powder suppression, pump stations and integration with fire alarm systems, voice evacuation and smoke control.
Get an approximate cost
AUPT: design, installation, equipment selection, testing. For manufacturing sites and business centers.
We design the system: suppression type, calculations, pump station. We integrate it with fire alarm systems and notification systems.
We install mains and distribution piping, mount sprinklers/deluge devices, and assemble valves and control nodes according to standards.
We install gas/powder/aerosol modules, connect and configure them. We implement activation and interlocks via fire alarm (OPS).
We configure automation and pumps, perform hydraulic tests, and verify operation with smoke control systems and SOUE.
AUPT for warehouses and commercial facilities: compliant design, installation and testing (water/gas/powder).
We plan each stage precisely: coordinate logistics and installation so your operations don’t stop, and deliver the system on time.
A team of engineers with real-world experience implementing water, gas and modular suppression systems: installation, commissioning and testing.
We integrate AUPT with OPS, SOUE, BMS and dispatching: scenarios, automation signals, interlocks and proper reporting.
We provide warranty for work and deliver scheduled inspections and preventive maintenance: monitoring components, assemblies and automation status.
AUPT workflow to ensure reliable operation and compliance with the design and regulatory requirements.
We inspect the facility, review layouts, room categories and existing systems. We define a clear technical brief to reduce rework and unnecessary costs.
We perform hydraulic calculations, select pipe diameters, sprinkler types, pump equipment and modules. The design follows applicable standards and requirements.
We install piping, sprinklers, control assemblies and shut-off valves, and connect the system to fire alarm systems and notification systems.
We connect AUPT to the pump station, backup power sources and control panels. We configure activation algorithms, delays, interlocks and feedback signals.
We run hydraulic tests, verify sprinklers and modules, simulate emergency scenarios and check interoperability with smoke control systems.
We prepare as-built documentation, support regulatory inspections and offer maintenance services with scheduled checks.
AUPT delivered for industrial, warehouse and office facilities: water, gas and powder solutions.
70,000 m² facility: water AUPT with a pump station and tanks, plus gas suppression for technical areas. Syrdarya region.
Water AUPT in storage chambers and gas suppression in machine rooms. Area 15,000 m², Tashkent region, Angren.
Gas AUPT implemented for server and technical rooms with OPS and SOUE integration, automation and interlocks. IT Park, Tashkent.
Equipment manufacturers we use for fire safety and AUPT projects.
TESCOM ENGINEERING designs and implements fire alarm systems and fire suppression systems for warehouses, manufacturing sites, shopping malls and office buildings. We deliver design, installation, commissioning, testing and maintenance as a single service: we integrate engineering systems into a unified infrastructure and support your facility through all stages of operation.
Short answers to common questions about automatic fire suppression systems.
The system includes actuation devices, piping, sprinklers or suppression modules, a pump station or cylinders, control assemblies, shut-off valves, and integration with the fire alarm and notification systems.
Water suppression is used in offices, malls, warehouses and parking facilities. Gas suppression is used in server rooms, data centers and archives. Powder suppression is used for local protection of electrical switchboards, production areas and fuel & lubricants storage.
Yes. The room must retain the gas for the required hold time, so we perform enclosure integrity checks, seal leakage points and adjust ventilation where needed.
Pricing depends on area and ceiling height, suppression type, tank or cylinder capacity, pipe length, pump station configuration, and the scope of installation and commissioning.
AUPT prices in Tashkent & Uzbekistan: design, installation, commissioning, service. Water/gas/powder.
| Service | Unit | Price, UZS |
|---|---|---|
| Sprinkler head installation | pc | from 480 000 |
| Deluge head installation | pc | from 520 000 |
| Gas suppression module installation | pc | from 2 800 000 |
| Powder suppression module installation | pc | from 1 950 000 |
| Aerosol suppression module installation | pc | from 2 300 000 |
| AUPT control valve installation | pc | from 3 200 000 |
| Section valve assembly installation | assembly | from 3 600 000 |
| Tank/capacity connection assembly installation | assembly | from 4 200 000 |
| Fire pump station installation | set | from 12 500 000 |
| Jockey/Fire Pump connection | set | from 3 800 000 |
| HD steel pipe DN15 (1") SCH40 installation | m | from 173 000 |
| HD steel pipe DN25 (1") SCH40 installation | m | from 206 000 |
| Pipe installation DN25–DN50 | m | from 80 000 |
| Pipe installation DN65–DN100 | m | from 105 000 |
| Main pipe installation DN125–DN200 | m | from 284 000 |
| Fire gate valves (manual/electric) installation | pc | from 650 000 |
| Check valve installation | pc | from 420 000 |
| Balancing valve installation | pc | from 520 000 |
| Water flow switch installation | pc | from 550 000 |
| Pressure sensor installation | pc | from 480 000 |
| Fire pump control cabinet installation | pc | from 4 800 000 |
| Connect AUPT to fire alarm (OPS) | facility | from 6 500 000 |
| Fire suppression commissioning | facility | from 9 500 000 |
| Hydraulic testing of piping | facility | from 13 200 000 |
| Check & adjust valves and control assemblies | facility | from 3 800 000 |
| System filling with water / solution | facility | from 2 500 000 |
| Fill with extinguishing gas (FM-200, Novec, CO₂) | kg | from 210 000 |
| AUPT repair & technical modernization | facility | by estimate |
| Monthly AUPT maintenance service | month | from 12 032 313 |
| Technical inspection of an existing system | facility | from 2 200 000 |
| AUPT design documentation & calculation | facility | from 7 300 000 |
| Refill fire suppression modules | pc | from 450 000 |
| Diagnostics & tuning of pressure/flow sensors | pc | from 150 000 |
| Turnkey AUPT installation (full scope) | facility | by estimate |
💡 The final cost depends on the suppression type (water, gas, powder), the volume of the protected areas, the fire pump station configuration, design requirements and the selected equipment. For an accurate estimate you can fill in the online form or send a request via the contact form. Integration with fire alarm systems and notification systems is available.
Get an exact estimateTESCOM ENGINEERING is an engineering and low-voltage systems company. We have an office in Tashkent, and our engineer can visit sites across the city and the region.